The MV-Series is Maxivolt’s original product line. Modifications through the years have improved the already legendary performance of these devices. The line has been expanded to 17 standard models covering virtually every type of AC power system in the world from 120 VAC to 600 VAC. Every device is hand made in the USA and goes through a rigorous and demanding testing process. MV-Series products feature hybrid circuits consisting of only the highest quality components engineered to provide an industry best clamping threshold for the specific voltage application they are designed for. Serviceable safety fusing and the non-ground dependent design eliminate safety risks associated with competitive devices. The various benefits of MV-Series products provide clients with a quantifiable payback.

THE MV-400P

  • Serviceable Safety Fusing
  • Hybrid Surge Suppression Circuit
  • No Ground Connection
  • Durable Catalyst Paint
  • Low Clamping Voltage
  • Low Surge Current Rating
  • 5 Year Warranty
  • ETL-EU Listed to IEC 61643-1

APPLICATION

Voltage

480 VAC

Configuration

3 Ø /3 Wire

CHARACTERISTICS

Fusing

Buss 5 Amp 600V KTK-5

Indication

Normally Off Neon Lights

Conductor

14 AWG Stranded

Markings

Silk Screened

Enclosure

NEMA® Type 3R

CERTIFICATIONS

Listing

ETL-EU IEC 61643-11

Environmental

RoHS

DIAGRAM

MV400P Diagram

SPECIFICATIONS

Modes of Protection

L-L

Type (Class)

2 (2)

Nominal Discharge Current

2 kA

Clamp Voltage

942

VPL

1360

SCCR

100 kA

MCOV

600

Operating Temperature

-40° C to 85° C

Operating Humidity

1% to 95%

Filtering

UL 1283

EMI-RFI Noise Attenuation

< 40 db

Capacitance

1 to 1.5 uF / Line

Component Response Time

< 1 ns

Rated Power Dissipation

<1 W / Line

Frequency Range

50 - 400 HZ

Degree of Protection

IP 20

STANDARD INSTALLATION SUMMARY

Install According To Instructions Provided With Device

  1. Remove 1/2” knockout.
  2. Mount using mounting feet with proper anchors.
  3. Connect one red conductor to phase A.
  4. Connect other red conductor to phase B.
  5. Connect last red conductor to phase C.
  6. Install fuses.

Note: Breaker Size 15 amp (if required).
Note: Never add length to provided conductors.
Note: For optimum SPD performance minimize conductor length and avoid sharp bends.

MAXIVOLT
Serious Surge Protection®
WS Series
Made in the USA

We'd love to hear from you

Contact Us

A team of power quality specialist to help you find a solution for your power quality issues. With vast experience and knowledge protecting industries from transient voltage, our team will help you with product selection, placement, and installation are critical to the performance of a surge protection system.

Send us a Message

logo

Phone

1-800-583-4773

Email

info@maxivolt.com

Need help?

Looks like you’ve been browsing for a bit.
Would you like to talk to a REAL person?