{"id":8996,"date":"2024-09-30T15:30:44","date_gmt":"2024-09-30T20:30:44","guid":{"rendered":"https:\/\/maxivolt.com\/home\/?p=8996"},"modified":"2026-10-12T15:03:12","modified_gmt":"2026-10-12T20:03:12","slug":"identifying-the-root-cause-of-motor-failure","status":"publish","type":"post","link":"https:\/\/maxivolt.com\/home\/identifying-the-root-cause-of-motor-failure\/","title":{"rendered":"Identifying the Root Cause of Motor Failure"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"8996\" class=\"elementor elementor-8996\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-3a120f72 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"3a120f72\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;,&quot;shape_divider_bottom_negative&quot;:&quot;yes&quot;,&quot;shape_divider_bottom&quot;:&quot;triangle&quot;}\">\n\t\t\t\t\t\t\t<div class=\"elementor-background-overlay\"><\/div>\n\t\t\t\t\t\t<div class=\"elementor-shape elementor-shape-bottom\" aria-hidden=\"true\" data-negative=\"true\">\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 1000 100\" preserveAspectRatio=\"none\">\n\t<path class=\"elementor-shape-fill\" d=\"M500.2,94.7L0,0v100h1000V0L500.2,94.7z\"\/>\n<\/svg>\t\t<\/div>\n\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-37e5633c elementor-hidden-tablet elementor-hidden-phone\" data-id=\"37e5633c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-65fc5b69 elementor-widget elementor-widget-heading\" data-id=\"65fc5b69\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Identifying the Root Cause of Motor Failure<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-63e3f860 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"63e3f860\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t\t<div class=\"elementor-background-overlay\"><\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-795a28a\" data-id=\"795a28a\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-94a89c5 elementor-widget elementor-widget-shortcode\" data-id=\"94a89c5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\"><div class=\"_df_book df-lite\" id=\"df_9019\"  _slug=\"identifying-the-root-cause-of-motor-failure\" data-title=\"identifying-the-root-cause-of-motor-failure\" wpoptions=\"true\" thumb=\"https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/Cover-Identifying-the-Root-Cause-of-Motor-Failure-1.png\" thumbtype=\"\" ><\/div><script class=\"df-shortcode-script\" nowprocket type=\"application\/javascript\">window.option_df_9019 = {\"outline\":[],\"backgroundColor\":\"#ffffff\",\"height\":\"500\",\"autoEnableOutline\":\"false\",\"autoEnableThumbnail\":\"false\",\"overwritePDFOutline\":\"false\",\"direction\":\"1\",\"pageSize\":\"0\",\"source\":\"https:\\\/\\\/maxivolt.com\\\/wp-content\\\/uploads\\\/2024\\\/09\\\/Identifying-the-Root-Cause-of-Motor-Failure.pdf\",\"wpOptions\":\"true\"}; if(window.DFLIP && window.DFLIP.parseBooks){window.DFLIP.parseBooks();}<\/script><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-823da9f elementor-widget elementor-widget-spacer\" data-id=\"823da9f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-94d1e65 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"94d1e65\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-inner-column elementor-element elementor-element-b60e084\" data-id=\"b60e084\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-e311edb elementor-widget elementor-widget-heading\" data-id=\"e311edb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Key Takeaways<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-f954b78 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"f954b78\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-e61428b\" data-id=\"e61428b\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6cd0a77 elementor-widget elementor-widget-text-editor\" data-id=\"6cd0a77\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li style=\"font-weight: 400;\" aria-level=\"1\"><p class=\"p1\">Ensure power quality environment and physical environment meet the motors needs.<\/p><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><p class=\"p1\">Ensure the motor is properly sized for the task.<\/p><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><p class=\"p1\">Avoid overloading the motor.<\/p><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><p class=\"p1\">Perform insulation quality checks on the motor regularly.<\/p><\/li><li style=\"font-weight: 400;\" aria-level=\"1\"><p class=\"p1\">Regular maintenance and lubrication can prolong motor life.<\/p><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-493cba0\" data-id=\"493cba0\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-5da7bab elementor-hidden-tablet elementor-hidden-mobile elementor-widget elementor-widget-image\" data-id=\"5da7bab\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/Identifying-the-Root-Cause-of-Motor-Failure.pdf\" target=\"_blank\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"213\" height=\"300\" src=\"https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/Thumbnail-Download-PDF-button-213x300.jpg\" class=\"attachment-medium size-medium wp-image-9001\" alt=\"Download PDF: Identifying the Root Cause of Motor Failure.\" srcset=\"https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/Thumbnail-Download-PDF-button-213x300.jpg 213w, https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/Thumbnail-Download-PDF-button-725x1024.jpg 725w, https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/Thumbnail-Download-PDF-button-768x1084.jpg 768w, https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/Thumbnail-Download-PDF-button-1088x1536.jpg 1088w, https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/Thumbnail-Download-PDF-button-1451x2048.jpg 1451w, https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/Thumbnail-Download-PDF-button-600x847.jpg 600w, https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/Thumbnail-Download-PDF-button-scaled.jpg 1813w\" sizes=\"(max-width: 213px) 100vw, 213px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-3ee001a elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"3ee001a\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-2984357\" data-id=\"2984357\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4ad87e9 elementor-widget__width-initial elementor-widget elementor-widget-image\" data-id=\"4ad87e9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/maxivolt.com\/wp-content\/uploads\/2023\/08\/ATS-Tech-Note.pdf\" target=\"_blank\">\n\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"534\" src=\"https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/electric-motor-repair-1024x683.jpg\" class=\"attachment-large size-large wp-image-8999\" alt=\"Technician working by hand on the exposed windings and wiring of an electric motor.\" srcset=\"https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/electric-motor-repair-1024x683.jpg 1024w, https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/electric-motor-repair-300x200.jpg 300w, https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/electric-motor-repair-768x512.jpg 768w, https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/electric-motor-repair-1536x1024.jpg 1536w, https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/electric-motor-repair-2048x1365.jpg 2048w, https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/electric-motor-repair-600x400.jpg 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-2882e41\" data-id=\"2882e41\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-a33a444 elementor-widget elementor-widget-heading\" data-id=\"a33a444\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Introduction<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2c0956b elementor-widget elementor-widget-text-editor\" data-id=\"2c0956b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"p1\">As motors become increasingly sophisticated, the potential for failure due to a combination of mechanical and electrical factors grows. Understanding the root cause of motor failures is essential to minimize costly downtime and ensure long-term reliability. While insulation breakdown and bearing wear are among the most common issues, failures can result from a wide range of sources.\u2076 Properly diagnosing these issues not only prevents unexpected disruptions but also enhances asset performance and extends motor lifespan. In this article, we\u2019ll explore key motor failure categories, both electrical and mechanical, and outline common causes and their impact on motor performance.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<div class=\"elementor-element elementor-element-7a1d803 elementor-widget elementor-widget-spacer\" data-id=\"7a1d803\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cc6cc6f elementor-widget elementor-widget-heading\" data-id=\"cc6cc6f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Motor Failure Categories<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-c782e82 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"c782e82\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-59522ff\" data-id=\"59522ff\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-c39b01e elementor-widget elementor-widget-text-editor\" data-id=\"c39b01e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"p1\">Motor failures fall into three basic categories: electrical, mechanical, and mechanical that progresses from electrical.<\/p><h4 class=\"p1\"><b>Electrical Causes of Motor Failure<\/b><\/h4><p class=\"p1\"><b>Transient voltage<\/b><\/p><p class=\"p1\">Short duration spikes in voltage within an electrical system (transient voltages) are caused by any sudden change in the system \u2013 such as equipment faults, switching loads, lightning strikes, etc.\u00b3 These power surges cause insulation breakdown and damage sensitive components within the motor, resulting in premature failure and downtime.<\/p><p class=\"p1\"><b>Voltage Imbalance<\/b><\/p><p class=\"p1\">Voltage imbalance refers to a condition in a three-phase electrical system where the magnitudes or phase angles of the voltages between the phases are not equal. Ideally, in a balanced system, the voltages in each phase are identical in magnitude and are evenly spaced at 120\u00b0 apart. When there is a voltage imbalance, one or more phases may experience higher or lower voltages than the others.\u00b2 An imbalance in a motor of 2% or greater decreases the motor\u2019s efficiency by generating extra heat within the motor, increasing its operating temperature and lowering its lifespan by decomposing the oil, grease or other components of the motor.<\/p><p class=\"p1\"><b>Harmonics<\/b><\/p><p class=\"p1\">Harmonics are voltage or current waveforms that appear to be the multiples of the fundamental frequency of the system.\u00b3 If the system\u2019s frequency is 60Hz, then the first harmonic would be 60Hz, the second would be 120Hz, and the third 180Hz. These can originate from variable frequency drives, power supplies, non-linear loads, transformer saturation, power factor correction capacitors, electronic devices and other industrial equipment within the system.<\/p><p class=\"p1\"><b>Sigma Currents <\/b><\/p><p class=\"p1\">Also known as residual currents and shaft currents, sigma currents occur when the sum of the currents do not equal zero. This can be caused by harmonics, a phase imbalance, or current on your neutral in single phase motors. The motor could see a reduction in efficiency, torque pulsations, and overheating as well as a decrease in lifespan if the motor is exposed to these sigma currents.\u00b2<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-4cfdc94\" data-id=\"4cfdc94\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-151732a elementor-widget elementor-widget-image\" data-id=\"151732a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"800\" height=\"482\" src=\"https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/voltage-imbalance-1.png\" class=\"attachment-large size-large wp-image-9044\" alt=\"Graph of red, yellow, and blue three-phase voltage waveforms with different amplitudes, illustrating voltage imbalance.\" srcset=\"https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/voltage-imbalance-1.png 860w, https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/voltage-imbalance-1-300x181.png 300w, https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/voltage-imbalance-1-768x463.png 768w, https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/voltage-imbalance-1-600x361.png 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Artesis. (2022, September 3). 10 most common failures in electric motors. Artesis. www.artesis.com\/10-most-common-failures-in-electric-motors\/<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5a9ec29 elementor-widget elementor-widget-spacer\" data-id=\"5a9ec29\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-466b281 elementor-widget elementor-widget-image\" data-id=\"466b281\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"512\" src=\"https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/sigma-current-768x512.jpeg\" class=\"attachment-medium_large size-medium_large wp-image-9006\" alt=\"Motor-current illustration showing high-frequency switching, a variable-frequency drive, and a highlighted path for sigma current returning through the motor and ground.\" srcset=\"https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/sigma-current-768x512.jpeg 768w, https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/sigma-current-300x200.jpeg 300w, https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/sigma-current-1024x683.jpeg 1024w, https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/sigma-current-600x400.jpeg 600w, https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/sigma-current.jpeg 1500w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Source: Lawal, G. (2022, May 10). Common causes of motor failure. Gilautomation. www.gilautomation.com\/blogs\/news\/common-causes-of-motor-failure<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-801b854 elementor-widget elementor-widget-text-editor\" data-id=\"801b854\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"p1\"><b>Overloads <\/b><\/p><p class=\"p1\">A motor can be overloaded if:<\/p><ol><li class=\"p1\">The mechanical load it is driving is greater than what the motor can perform or the load changes too frequently<\/li><li class=\"p1\">The supply voltage is too low for the motor to operate at an efficiency<\/li><li class=\"p1\">The ambient temperature is too high and the motor is unable to cool efficiently<\/li><li class=\"p1\">The motor has a faulty component (such as the rotor or bearings) that cause it to work harder and thus overheat.<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<div class=\"elementor-element elementor-element-de08dda elementor-widget elementor-widget-spacer\" data-id=\"de08dda\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-3736e0c elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"3736e0c\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-49e1e97\" data-id=\"49e1e97\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-66dbc3c elementor-widget elementor-widget-text-editor\" data-id=\"66dbc3c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h4><b>Mechanical Causes <\/b><b>of Motor Failure<\/b><\/h4><p class=\"p1\"><b>Misalignment<\/b><\/p><p class=\"p1\">This occurs when the motor\u2019s shaft is not properly aligned with the driven equipment shaft (pump, fan, gearbox, etc.). This could be caused from improper installation, wear, and tear, foundation settling, thermal expansion, or even just vibrations alone.\u2075<\/p><p class=\"p1\"><b>Shaft Imbalance <\/b><\/p><p class=\"p1\">Shaft Imbalance develops when the mass distribution of the rotor or shaft is uneven, causing the center of mass to deviate from the axis of rotation. This imbalance results in uneven centrifugal forces during operation, leading to vibration, noise, and excessive wear on motor components.\u00b2 This problem can stem from manufacturing defects, wear and tear, operational damage, material build up, or unbalanced add-ons to the machine.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-54fcfff\" data-id=\"54fcfff\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-794530d elementor-widget elementor-widget-text-editor\" data-id=\"794530d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"p1\"><b>Bearing Wear<\/b><\/p>\n<p class=\"p1\">Bearings wear normally through use, but certain aspects can stunt this vital component\u2019s lifespan. They can wear more quickly due to friction, heat, contamination, improper lubrication, or misalignment.<\/p>\n<p class=\"p1\"><b>Insulation Breakdown<\/b><\/p>\n<p class=\"p1\">Insulating material around the motor windings helps keep the phases separated and prevents electrical current from intermingling between the phases and\/or the motor frame.\u00b9 Causes of insulation breakdown include overheating, stress (whether electrical or mechanical), contamination, age, or partial electrical discharge.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<div class=\"elementor-element elementor-element-adec0c3 elementor-widget elementor-widget-spacer\" data-id=\"adec0c3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a90ee81 elementor-widget elementor-widget-heading\" data-id=\"a90ee81\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Preventing Motor Failures: Proactive Strategies<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-0e91826 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"0e91826\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-a813702\" data-id=\"a813702\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-783db2f elementor-widget elementor-widget-text-editor\" data-id=\"783db2f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"p1\">To minimize the risk of motor failure, both electrical and mechanical factors must be addressed through a comprehensive maintenance and monitoring strategy. By implementing preventive measures, you can extend the lifespan of your motor, reduce downtime, and enhance overall system reliability.<\/p><p class=\"p1\">Here are some key strategies to help prevent the common issues discussed above.<\/p><h4 class=\"p1\"><b>Preventing Electrical Failures<\/b><\/h4><p class=\"p1\"><b>Transient Voltage:<\/b><\/p><p class=\"p1\"><a href=\"https:\/\/maxivolt.com\/home\/persistent-equipment-failures-despite-spd-usage\/\">Properly sized and applied Surge Protection Devices (SPDs)<\/a> mitigate the effects of random, extreme spikes in voltage. This will protect your motor and help it maintain a smoother electrical experience as long as grounding is sound, and the voltages are already balanced.<\/p><p class=\"p1\"><b>Voltage Imbalance: <\/b><\/p><p class=\"p2\">Install voltage monitors and voltage regulators to safeguard motors against imbalances and ensure consistency. Regularly inspect the electrical supply to ensure balanced voltages, verify the cable sizing is sized appropriately, and clean connections across all phases. If power factor correction is needed, an appropriately sized capacitor bank could be used to help balance out the voltages.<\/p><p class=\"p1\"><b>Harmonics: <\/b><\/p><p class=\"p1\">Use harmonic filters (passive or active filters) to minimize the impact of harmonic distortion from non-linear loads. Harmonic filters, line conditioners, inductors, and capacitors, provide low impedance paths at the selected frequencies. Additionally, maintain proper power factor correction systems and review the compatibility of drives with your system to mitigate harmonic generation. These need to be placed near non-linear loads to help control the harmonics effects on the rest of the power system. Another way to mitigate harmonics is to use <a href=\"https:\/\/maxivolt.com\/home\/solutions-to-common-vfd-faults\/\">AC line reactors and DC link chokes<\/a> because they reduce the peaks of the inrush current caused by Variable Frequency Drive inverters.<\/p><p class=\"p1\"><b>Sigma Currents (Residual Currents): <\/b><\/p><p class=\"p2\">Regular monitoring with advanced motor protection relays and residual current devices (RCDs) can help detect phase imbalances and neutral current issues early on, reducing overheating and inefficiency. Balancing the load and ensuring proper wiring practices are also essential in controlling sigma currents.<\/p><p class=\"p1\"><b>Overloads:<\/b><\/p><p class=\"p2\">Prevent motor overloads by properly sizing the motor for the load it drives. Ensure the motor is operated within its design limits by monitoring the load, supply voltage, and ambient temperature. Use overload relays or motor protection devices to automatically shut down the motor when overloading occurs.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-c6769da\" data-id=\"c6769da\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8334d1d elementor-widget elementor-widget-image\" data-id=\"8334d1d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"274\" src=\"https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/shaft_misalignment-300x274.jpeg\" class=\"attachment-medium size-medium wp-image-9007\" alt=\"Diagrams comparing angular shaft misalignment, where shafts meet at an angle, with parallel misalignment, where their centerlines are offset.\" srcset=\"https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/shaft_misalignment-300x274.jpeg 300w, https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/shaft_misalignment-1024x935.jpeg 1024w, https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/shaft_misalignment-768x701.jpeg 768w, https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/shaft_misalignment-1536x1402.jpeg 1536w, https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/shaft_misalignment-2048x1870.jpeg 2048w, https:\/\/maxivolt.com\/wp-content\/uploads\/2024\/09\/shaft_misalignment-600x548.jpeg 600w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Source: Fluke. 13 common causes of motor failure. Fluke. www.fluke.com\/en-gb\/learn\/blog\/motors-drives-pumps-compressors\/13-common-causes-of-motor-failure<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d1c5c64 elementor-widget elementor-widget-text-editor\" data-id=\"d1c5c64\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h4 class=\"p1\"><b>Preventing Mechanical Failures<\/b><\/h4><p class=\"p1\"><b>Misalignment:<\/b><\/p><p class=\"p2\">Misalignment is often a result of poor installation practices. Conduct an alignment check between the motor and the driven equipment using laser alignment tools. This will ensure the shafts are properly aligned, preventing excessive wear and vibration.\u2075<\/p><p class=\"p1\"><b>Shaft Imbalance:<\/b><\/p><p class=\"p2\">Ensure that rotors and shafts are properly balanced during both installation and maintenance. Periodically clean the motor to prevent material buildup that could lead to imbalance. If vibrations or noise develop, conduct a balancing test immediately to prevent damage.\u00b2<\/p><p class=\"p1\"><b>Bearing Wear:<\/b><\/p><p class=\"p2\">To prevent premature bearing wear, use the correct type and grade of lubricant, and follow the manufacturer\u2019s recommended lubrication schedule. Avoid over-lubrication, which can cause excess heat and lead to bearing failure. Also, keep the motor and surrounding environment clean to prevent contamination from debris or moisture.\u2077<\/p><p class=\"p1\"><b>Insulation Breakdown:<\/b><\/p><p class=\"p2\">Regularly inspect and test motor insulation to detect early signs of deterioration. Use insulation resistance testing (megger tests). For high voltage, use apartial discharge analysis to assess the condition of the insulation.\u00b9<\/p><p class=\"p2\">Maintain proper ventilation and cooling systems to prevent the motor from overheating (a major cause of insulation breakdown).\u00b9 Keep the motor clean to prevent blockages in airways and ensure that fans are functioning correctly.<\/p><p class=\"p2\">Finally, shield the motor from contaminants (dust, moisture, and corrosive chemicals) by using appropriate enclosures.\u00b9<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<div class=\"elementor-element elementor-element-981a940 elementor-widget elementor-widget-spacer\" data-id=\"981a940\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8998708 elementor-widget elementor-widget-heading\" data-id=\"8998708\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conclusion<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-057e223 elementor-widget elementor-widget-text-editor\" data-id=\"057e223\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"p1\">Identifying the root cause of motor failures is essential for maintaining the efficiency and reliability of industrial operations. Motor issues can stem from a variety of electrical and mechanical factors, each with its own set of symptoms and impacts. Electrical problems such as transient voltage spikes, voltage imbalances, harmonics, sigma currents, and overloads can lead to significant disruptions if not promptly addressed. Similarly, mechanical issues including misalignment, shaft imbalance, bearing wear, and insulation breakdown can exacerbate problems and lead to premature motor failure.<\/p><p class=\"p1\">Understanding these potential causes allows for more effective troubleshooting and preventive measures. By conducting regular maintenance, monitoring performance indicators, and addressing issues as they arise, organizations can reduce downtime, extend motor life, and enhance overall operational efficiency. Proactive management and accurate diagnosis are key to mitigating risks and ensuring the continued success of motor-driven systems.<\/p><p data-start=\"146\" data-end=\"344\" data-is-last-node=\"\" data-is-only-node=\"\">Start upstream. Contact Maxivolt to evaluate transient voltage and power quality in your system\u2014and implement protection that reduces stress, improves efficiency, and prevents repeat motor failures.<\/p><p data-start=\"146\" data-end=\"344\" data-is-last-node=\"\" data-is-only-node=\"\"><a class=\"dark btn\" href=\"https:\/\/maxivolt.com\/home\/proven-process\/\">get started<\/a><\/p><p data-start=\"146\" data-end=\"344\" data-is-last-node=\"\" data-is-only-node=\"\">\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-86e7387 elementor-widget elementor-widget-heading\" data-id=\"86e7387\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Resources<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4f751df elementor-widget elementor-widget-text-editor\" data-id=\"4f751df\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ol><li class=\"p1\"><p class=\"p1\"><span class=\"s1\">Kruger, B. (2022, July 8).<i> Electrical insulation failure.<\/i> CBM CONNECT\u00ae. <a href=\"http:\/\/www.cbmconnect.com\/electrical-insulation-failure-2\/\" target=\"_blank\" rel=\"noopener\">www.cbmconnect.com\/electrical-insulation-failure-2\/<\/a><\/span><\/p><\/li><li class=\"p1\"><p class=\"p1\"><span class=\"s1\">Artesis. (2022, September 3). <i>10 most common failures in electric motors. <\/i>Artesis. <a href=\"http:\/\/www.artesis.com\/10-most-common-failures-in-electric-motors\/\" target=\"_blank\" rel=\"noopener\">www.artesis.com\/10-most-common-failures-in-electric-motors\/<\/a><\/span><\/p><\/li><li class=\"p1\"><p class=\"p1\"><span class=\"s1\">Lawal, G. (2022, May 10). C<i>ommon causes of motor failure.<\/i> Gilautomation. <a href=\"http:\/\/www.gilautomation.com\/blogs\/news\/common-causes-of-motor-failure\" target=\"_blank\" rel=\"noopener\">www.gilautomation.com\/blogs\/news\/common-causes-of-motor-failure<\/a><\/span><\/p><\/li><li class=\"p1\"><p class=\"p1\"><span class=\"s1\">Bolotinha, Manuel. (2022, September 29). <i>Motor protection \u2013 Types of faults and protection devices<\/i>. Electrical Technology. <a href=\"http:\/\/www.electricaltechnology.org\/2020\/10\/motor-protection-types-faults-protection-devices.html\" target=\"_blank\" rel=\"noopener\">www.electricaltechnology.org\/2020\/10\/motor-protection-types-faults-protection-devices.html<\/a><\/span><\/p><\/li><li class=\"p1\"><p class=\"p1\"><span class=\"s1\">Butcher, J. (2022, December 5). <i>Common causes of motor failure &amp; how to prevent them. <\/i>Energy Management Corporation. <a href=\"http:\/\/www.goemc.com\/2021\/04\/09\/common-causes-of-motor-failure-how-to-prevent-them\/\" target=\"_blank\" rel=\"noopener\">www.goemc.com\/2021\/04\/09\/common-causes-of-motor-failure-how-to-prevent-them\/<\/a><\/span><\/p><\/li><li class=\"p1\"><p class=\"p1\"><span class=\"s1\">Duke Electric. (2024, July 30). <i>The essential guide to electric motor failure. <\/i>Duke Electric. <a href=\"http:\/\/www.dukeelectric.com\/motors\/failure\/guide\/\" target=\"_blank\" rel=\"noopener\">www.dukeelectric.com\/motors\/failure\/guide\/<\/a><\/span><\/p><\/li><li class=\"p1\"><p class=\"p1\"><span class=\"s1\">Fluke. <i>13 common causes of motor failure. <\/i>Fluke. <a href=\"http:\/\/www.fluke.com\/en-gb\/learn\/blog\/motors-drives-pumps-compressors\/13-common-causes-of-motor-failure\" target=\"_blank\" rel=\"noopener\">www.fluke.com\/en-gb\/learn\/blog\/motors-drives-pumps-compressors\/13-common-causes-of-motor-failure<\/a><\/span><\/p><\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7402a898 elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"7402a898\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ff9be5c elementor-widget elementor-widget-heading\" data-id=\"ff9be5c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h6 class=\"elementor-heading-title elementor-size-default\">Share This:<\/h6>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-03dd1d4 elementor-share-buttons--view-icon elementor-share-buttons--shape-circle elementor-share-buttons--skin-gradient elementor-grid-0 elementor-share-buttons--color-official elementor-widget elementor-widget-share-buttons\" data-id=\"03dd1d4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"share-buttons.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-grid\" role=\"list\">\n\t\t\t\t\t\t\t\t<div class=\"elementor-grid-item\" role=\"listitem\">\n\t\t\t\t\t\t<div class=\"elementor-share-btn elementor-share-btn_facebook\" role=\"button\" tabindex=\"0\" aria-label=\"Share on facebook\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-share-btn__icon\">\n\t\t\t\t\t\t\t\t<i class=\"fab fa-facebook\" aria-hidden=\"true\"><\/i>\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-grid-item\" role=\"listitem\">\n\t\t\t\t\t\t<div class=\"elementor-share-btn elementor-share-btn_twitter\" role=\"button\" tabindex=\"0\" aria-label=\"Share on twitter\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-share-btn__icon\">\n\t\t\t\t\t\t\t\t<i class=\"fab fa-twitter\" aria-hidden=\"true\"><\/i>\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-grid-item\" role=\"listitem\">\n\t\t\t\t\t\t<div class=\"elementor-share-btn elementor-share-btn_linkedin\" role=\"button\" tabindex=\"0\" aria-label=\"Share on linkedin\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-share-btn__icon\">\n\t\t\t\t\t\t\t\t<i class=\"fab fa-linkedin\" aria-hidden=\"true\"><\/i>\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>As motors become increasingly sophisticated, the potential for failure due to a combination of mechanical and electrical factors grows. Understanding the root cause of motor failures is essential to minimize costly downtime and ensure long-term reliability.<\/p>\n","protected":false},"author":6,"featured_media":8999,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_coblocks_attr":"","_coblocks_dimensions":"","_coblocks_responsive_height":"","_coblocks_accordion_ie_support":"","footnotes":""},"categories":[118],"tags":[135,119],"class_list":["post-8996","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-tech-note","tag-industry-specific-applications","tag-tech-note"],"_links":{"self":[{"href":"https:\/\/maxivolt.com\/home\/wp-json\/wp\/v2\/posts\/8996","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/maxivolt.com\/home\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/maxivolt.com\/home\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/maxivolt.com\/home\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/maxivolt.com\/home\/wp-json\/wp\/v2\/comments?post=8996"}],"version-history":[{"count":41,"href":"https:\/\/maxivolt.com\/home\/wp-json\/wp\/v2\/posts\/8996\/revisions"}],"predecessor-version":[{"id":16136,"href":"https:\/\/maxivolt.com\/home\/wp-json\/wp\/v2\/posts\/8996\/revisions\/16136"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/maxivolt.com\/home\/wp-json\/wp\/v2\/media\/8999"}],"wp:attachment":[{"href":"https:\/\/maxivolt.com\/home\/wp-json\/wp\/v2\/media?parent=8996"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/maxivolt.com\/home\/wp-json\/wp\/v2\/categories?post=8996"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/maxivolt.com\/home\/wp-json\/wp\/v2\/tags?post=8996"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}